Serial Communications
Q-750i Series Installation/Operation Manual 77
PRE
L
IMINAR
Y
Input: op sharp.mode = 1 [CR]
Response: OP SHARP.MODE = 1 [CR]
Input: op sharp.simple = 50 [CR]
Response: OP SHARP.SIMPLE = NA [CR]
Input: op sharp.simple ? [CR]
Response: OP SHARP.SIMPLE = NA [CR]
The last three commands show what happens when a control is grayed out. In this case,
the sharpness mode was set to advanced (value = 1) and then the simple sharpness slider
was attempted to be adjusted and queried. The response was “NA” or not available.
Table 6-2. Serial Commands
Operation Commands Values Notes
aspect = ?
0 = 16:9
1 = Letterbox
2 = 4:3
3 = VirtualWide
4 = Cinema
5 = VirtualCinema
memory = ?
0 = Custom 1
1 = Custom 2
2 = ISF Day
3 = ISF Night
4 = Default
? returns a value only if
ISF Day or ISF Night is
active, otherwise it returns
NA.
save.mem =
0 = Custom 1
1 = Custom 2
save.isf =
0 = ISF Day
1 = ISF Night
bright
contrast
saturat
tint
sharp
nr
= ? + -
0 - 200
overscan = ?
0 = Off
1 = Crop
2 = Zoom
source.sel = ?
0 = HDMI 1
1 = HDMI 2
2 = RGB
3 = Component 1
4 = Component 2
5 = S-Video
6 = Video
7 = SCART